TradesPro 837254 Manual de Utilização e Manutenção

Consulte online ou descarregue Manual de Utilização e Manutenção para Compressores de ar TradesPro 837254. TradesPro 837254 Use and Care Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 3
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
MAINTENANCE
Disconnect air compressor from power source and bleed
off all air pressure before attempting any maintenance or repair
.
SHUTDOWN AND STORAGE:
NEVER stop the air compressor by unplugging it from the
power outlet as this may result in damage to the compressor.
1. Turn the switch to the OFF position
2. Disconnect the power cord from the power outlet. Disconnect the power cord
from the power outlet by grabbing the plug (not the cord). Loop around electric
cord holder for storage.
3. Turn the pressure regulator knob fully counterclockwise to close airflow from
air outlet port. Check the outlet pressure gauge to ensure that it reads 0 PSI.
4. Remove the air hose and any air accessories.
5. Drain moisture from the air tank by slowly opening the air tank drain valve by
turning counter clockwise. Tilt tank to remove all moisture. Once all the mois-
ture has drained out, close the fitting securely.
6. Allow the compressor to cool down.
7. Wipe the air compressor clean and store it in a clean, dry, and non-freezing location.
WHEN PERFORMING ANY MAINTENANCE OR SERVICE:
1. The air compressor must be turned off.
2.
Disconnect compressor from the power source.
3. Open tank drain to bleed off all air pressure before attempting any maintenance
or repair.
4. Allow compressor to fully cool before attempting any maintenance or repair.
Check the air compressor frequently for any visible problems and follow mainte-
nance procedures each time the compressor is used.
MAINTENANCE CHECKLIST:
Daily:
Drain accumulated liquid from tank.
Check for unusual noise and/or vibrations.
Check that all fasteners are secure.
Wipe compressor clean.
14
Vista de página 0
1 2 3

Resumo do Conteúdo

Página 1

MAINTENANCE Disconnect air compressor from power source and bleedoff all air pressure before attempting any maintenance or repair.SHUTDOWN AND STORAGE

Página 2 - PROBABLE CAUSE: SOLUTION:

Monthly:• Check for air leaks.MOISTURE IN COMPRESSED AIRMoisture is a normal by-product of compressing air. As the moisture builds duringcompressor us

Página 3

Pressure regulator knob is Adjust pressure regulator knob to proper setting. not turned to high enough pressure.Defective motor ON/OFF Replace.switch

Comentários a estes Manuais

Sem comentários